ERO 6180

    Specifications

    Scanning head

    AK ERO 6180

    Interface

     1 VPP

    Reference mark signal

    Square-wave pulse

    Cutoff frequency –3 dB

    200 kHz

    Electrical connection

    Cable 3 m with D-sub connector (male), 15-pin

    Cable length

    30 m

    Voltage supply

    DC 5 V ±0.25 V

    Current consumption

    < 100 mA (without load)

    Vibration 55 to 2000 Hz

    Shock 6 ms

    200 m/s2 (EN 60 068-2-6)

    500 m/s2 (EN 60 068-2-27)

    Operating temperature

    0 °C to 50 °C (32 °F to 122 °F)

    Mass Scanning head

    Connector

    Cable

    ≈ 6 g (without cable)

    ≈ 32 g

    ≈ 22 g/m

    Circular scale

    TKN ERO 6100

    Measuring standard

    Chrome graduation on glass

    Signal periods

    4096

    Accuracy of graduation

    ±10”

    Interpolation error per signal period1)

    ±5”

    Reference marks

    One

    Hub inside diameter

    41 mm

    Circular scale outside diameter

    70 mm

    Mech. permissible speed

    3500 rpm

    Moment of inertia

    50 x 10–6 kgm2

    Permissible axial motion

    0.1 mm

    Protection EN 60 529

    Complete encoder in mounted position: IP00

    Mass

    ≈ 71 g

    1) Interpolation error within one signal period and the accuracy of the graduation together result in the encoder-specific error; for additional error from mounting and bearing of the measured shaft, see Measuring accuracy