Scale |
LIC 2107 |
||||
Measuring standard Coefficient of linear expansion |
Steel scale tape with absolute track αtherm 10 x 10–6 K–1 |
||||
Accuracy grade |
±15 µm |
||||
Measuring length ML* in mm |
120 320 520 770 1020 1220 1520 2020 2420 3020 (measuring lengths greater than 6020 mm upon request) |
||||
Mass Scale tape Scale-tape carrier |
20 g/m 70 g/m |
||||
Scanning head |
LIC 211 |
LIC 219 F |
LIC 219 M |
LIC 219 P |
|
Interface |
EnDat 2.2 |
Fanuc Serial Interface αi interface |
Mitsubishi high speed interface |
Panasonic serial interface |
|
Ordering designation* |
EnDat22 |
Fanuc05 |
Mit03-4 |
Mit02-2 |
Pana01 |
Measuring step* |
0.1 µm (100 nm) 0.05 µm (50 nm) |
||||
Calculation time tcal Clock frequency |
≤ 5 µs ≤ 16 MHz |
– – |
|||
Traversing speed1) |
≤ 600 m/min |
||||
Interpolation error |
±2 µm |
||||
Electrical connection* |
Cable, 1 m or 3 m with 8-pin M12 coupling (male) or 15 D-sub connector (male) |
||||
Cable length (with HEIDENHAIN cable) |
≤ 100 m |
≤ 50 m |
≤ 30 m |
≤ 50 m |
|
Voltage supply |
DC 3.6 V to 14 V |
||||
Power consumption1) (max.) |
At 3.6 V: ≤ 700 mW At 14 V: ≤ 800 mW |
At 3.6 V: ≤ 850 mW At 14 V: ≤ 950 mW |
|||
Current consumption |
At 5 V: 75 mA (without load) |
At 5 V: 95 mA (without load) |
|||
Vibration 55 Hz to 2000 Hz Shock 6 ms |
≤ 500 m/s2 (EN 60068-2-6) ≤ 1000 m/s2 (EN 60068-2-27) |
||||
Operating temperature |
–10 °C to 70 °C |
||||
Mass Scanning head Connecting cable Connector |
≤ 18 g (without cable) 20 g/m M12 coupling: 15 g; D-sub connector: 32 g |
||||
* Please select when ordering 1) See General electrical information in the brochure Interfaces of HEIDENHAIN Encoders |