Specifications |
IBV 101 |
||||||||
Input |
1 VPP |
||||||||
Electrical connection |
M23 flange socket (female) 12-pin |
||||||||
Cable length |
≤ 60 m for UP > 4.9 V ≤ 30 m at IEncoder ≤ 120 mA |
||||||||
Interpolation1) |
IBV 101: 5-fold, 10-fold IBV 102: 20-fold, 25-fold, 50-fold, 100-fold |
||||||||
Input frequency1) for interpolation |
Nominal values2) |
||||||||
IBV 101 |
5-fold |
200 kHz |
200 kHz |
133 kHz |
100 kHz |
80 kHz |
50 kHz |
25 kHz |
|
10-fold |
200 kHz |
100 kHz |
66 kHz |
50 kHz |
40 kHz |
25 kHz |
12.5 kHz |
||
IBV 102 |
20-fold |
100 kHz |
50 kHz |
33 kHz |
25 kHz |
20 kHz |
12.5 kHz |
6.25 kHz |
|
25-fold |
80 kHz |
40 kHz |
26 kHz |
20 kHz |
16 kHz |
10 kHz |
5 kHz |
||
50-fold |
40 kHz |
20 kHz |
13 kHz |
10 kHz |
8 kHz |
5 kHz |
2.5 kHz |
||
100-fold |
20 kHz |
10 kHz |
6.6 kHz |
5 kHz |
4 kHz |
2.5 kHz |
1.25 kHz |
||
Output1) |
TTL (clocked) |
||||||||
Electrical connection |
M23 flange socket (male) 12-pin |
||||||||
Cable length |
≤ 25 m |
≤ 50 m |
≤ 75 m (Uas ≤ 50 m) |
≤ 100 m (Uas ≤ 50 m) |
|||||
Edge separation a |
≥ 0.100 µs |
≥ 0.220 µs |
≥ 0.345 µs |
≥ 0.465 µs |
≥ 0.585 µs |
≥ 0.950 µs |
≥ 1.925 µs |
||
Reference mark signal1) |
Pulse width 90° elec. or 270° elec. |
||||||||
Fault indication1) |
through fault detection signal Uas or, in addition, Ua1/Ua2 high impedance |
||||||||
Power supply |
5 V ± 5 % |
||||||||
Current consumption3) |
IBV 101: ≤ 120 mA IBV 102: ≤ 130 mA |
||||||||
Operating temperature Storage temperature |
0 °C to 70 °C –30 °C to 80 °C |
||||||||
Vibration 50 to 2 000 Hz Shock 11 ms |
≤ 100 m/s2 ≤ 300 m/s2 |
||||||||
Degree of protection |
IP 65 |
||||||||
Weight |
Approx. 0.3 kg |
||||||||
Bold: This version is the factory default setting, please select when ordering 1) Adjustable 2) The actual input frequency can be up to 5% lower. Exceeding this limit results in failure 3) Not including output load (80 mA with recommended input circuitry) or the current consumption of the encoder |